title: "Control of Electro-Magnetic Field Regulations at Work"
description: "It is now approaching 12 months since the Control of Electromagnetic Fields at Work Regulations 2016 came into force. HSE normally allow employers some 12 months to recognise that new regulations have emerged and therefore are likely to begin to ask questions of employers during..."
canonical: "https://www.safety-management.co.uk/news/control-of-electro-magnetic-field-regulations-at-work"
type: "Article"
publishedAt: "2017-05-30T10:15:17"
modifiedAt: "2020-08-17T10:34:07"
keywords: "Uncategorised"
---

# Control of Electro-Magnetic Field Regulations at Work

It is now approaching 12 months since the Control of Electromagnetic Fields at Work Regulations 2016 came into force. HSE normally allow employers some 12 months to recognise that new regulations have emerged and therefore are likely to begin to ask questions of employers during...

Canonical URL: https://www.safety-management.co.uk/news/control-of-electro-magnetic-field-regulations-at-work

## Article

It is now approaching 12 months since the Control of Electromagnetic Fields at Work Regulations 2016 came into force. HSE normally allow employers some 12 months to recognise that new regulations have emerged and therefore are likely to begin to ask questions of employers during inspections as to how the Company is proposing to comply if the hazard is present. These have very little application for the vast majority of employers unless there are employees with active or inactive medical implant medical devices (e.g. pacemakers, neuro simulators, drug infusion pumps). If there are no employees or other people with such devices then the risks are much lower.

Employees and others close to the following may be exposed to levels above those set within the regulations and may need considering under a specific risk assessment:

- Broadcast and telecoms base stations, inside operator’s designated exclusion zone
- Radio frequency or microwave energised lighting equipment Radio and TV broadcasting systems and devices
- Any electrical circuit or installation (including cables, busbars, switchgear and transformers), where the cables carrying the electrical currents are bundled together so that they are always touching or nearly so, but there are earthing arrangements that mean the cables collectively carry an unbalanced current of >100 A
- Any electrical circuit or installation (including cables, busbars, switchgear and transformers), where the cables or busbars carrying the electrical currents are separated, and the rating of the circuit or that part of it is >100 A (equivalent to 23 kW for a single-phase 230 V circuit, 69 kW for a three-phase 230 V circuit, or 1.9 MW for a three-phase 11 kV circuit)
- Dielectric heating and welding
- Resistance welding: manual spot and seam welding Induction heating Induction soldering
- Magnetic particle inspection (crack detection)
- Industrial magnetiser and demagnetisers, eg tape erasers
- Microwave heating and drying
- RF plasma devices including vacuum deposition and sputtering
- Industrial electrolysis Furnaces, arc and induction melting
- Microwave drying in the construction industry
- Medical MRI equipment Medical diagnostic and treatment equipment using EMFs, eg diathermy and transcranial magnetic stimulation
- Electrically-powered trains and trams

For further guidance the HSE have published a guide to the regulations, with further information as to whether a specific assessment is required. This is available at: [www.hse.gov.uk/pubns/priced/hsg281.pdf](http://www.hse.gov.uk/pubns/priced/hsg281.pdf)

## Related guidance

- [Practical Health & Safety Support: Knowing Where to Start and What to Do Next](/news/practical-health-safety-support-knowing-where-to-start-and-what-to-do-next): Managing health and safety can feel straightforward when everything is running smoothly. Policies have been written, risk assessments have been completed, and there have been no recent incidents. However, many organisations reach a point where they begin to ask more fundamental...
- [Why Retained Health & Safety Support Gives Leaders Greater Confidence](/news/why-retained-health-safety-support-gives-leaders-greater-confidence): For senior operations, health and safety and facilities leaders, the challenge is rarely a lack of documentation. Most organisations already have policies, risk assessments and procedures in place, and many have competent people responsible for maintaining them. The more difficu...
- [How Workplace Safety Audits Help You Focus on What Actually Matters](/news/how-workplace-safety-audits-help-you-focus-on-what-actually-matters): A workplace safety audit is often associated with compliance, paperwork and preparing for inspections. While these are all important aspects of health and safety management, they are not the primary reason for carrying out an audit. The real value of a workplace safety audit UK...
- [What Should You Do After a Near Miss in the Workplace? A Practical Guide for Businesses](/news/what-should-you-do-after-a-near-miss-in-the-workplace-a-practical-guide-for-businesses): A near miss in the workplace is an incident that had the potential to cause injury, ill health, damage to property or interruption to business operations but, fortunately, did not result in harm. While it may be tempting to regard these incidents as isolated events because no on...

## Explore local coverage

- [Explore local coverage](/locations): Browse support across regions, towns, services and sectors.
- [Health & Safety Consultancy in Bedfordshire](/services/health-safety/bedfordshire): Health & Safety Consultancy coverage linked to Bedfordshire businesses and surrounding towns.
- [Construction support in Bedfordshire](/sectors/construction/bedfordshire): Construction guidance connected to Bedfordshire operations and site risk.
- [Health & Safety Consultancy in Bedford](/services/health-safety/bedfordshire/bedford): Health & Safety Consultancy support for Bedford and nearby areas including Luton, Dunstable.